CAPCO HI-WALL SYSTEM 6M HIGH
Vertical Studs: 102 x 35 x 6.5 x 0.6mm at 400mm centres
Top & Bottom Tracks: 103 x 30 x 0.6mm
Horizontal Noggings: 38 x 12 x 1.00mm at 1.800m centres.
Nogging Fixing: 70 x 25 x 25 x 0.8mm Galvanised Angles fixed to studs with 4.2 x 3mm Wafertek screws.
Boarding: 15mm tapered edge “Fireshield” gypsum board fixed to each side of partition. Staggered joints.